Transformer Oils Breakdown Voltage Tester TOR-80A (TOR-80 ASL) with battery
The TOR-80A (TOR-80 ASL) tester is specifically designed for assessing transformer oil and other liquid dielectrics by determining their electrical breakdown voltage. This breakthrough voltage measurement adheres to standards such as IEC 60156, VDE 0370, ASTM D877, ASTM D1816, and IRAM 2341. It’s worth noting that this list of standards can be adjusted and expanded to align with customer preferences and evolving standards.
One notable feature of the TOR-80A (TOR-80 ASL) tester is its built-in rechargeable battery, enabling autonomous operation in the field where transformers are in use.
Testing Procedure
Upon filling the measuring cell with oil and switching on the device, the start screen appears on the display. The operator then selects the oil type and the testing procedure. TOR-80A initiates the testing process automatically. The cumulative results are presented on the display following the completion of the last test cycle breakthrough. If necessary, these result summaries can be directly transferred to a printer from the tester.
№ |
Item |
Value |
1 |
Operating AC voltage, V |
85 – 264 |
2 |
AC frequency of the power network, Hz |
48 – 63 |
3 |
Electrical power, VA |
70 max |
4 |
Max. output voltage, kV |
Sinusoidal, up to 80 kV RMS |
5 |
Output voltage measurement accuracy, % |
± 1 |
6 |
Voltage increase rate, kV/sec (adjustable) |
0.5 – 10.0 |
7 |
Measurement limit when displaying the output voltage, V |
100 |
8 |
High voltage timeout after breakthrough, µs |
10 max, 4 typical |
9 |
Measuring cell roominess, cm3 |
500 |
10 |
Temperature measurement range, °C (°F) |
0 – 100 (32 – 212) |
11 |
Temperature measurement limit, °С |
1 |
12 |
Built-in printer |
yes |
13 |
Rechargable battery pack |
yes |
14 |
Time of continuous autonomous operation (from battery), h |
8 |
15 |
Battery charging time, h |
8 |
16 |
Operating temperature, °С |
-10 – 50 (14 – 122) |
17 |
Transportation and storage temperature, °C |
From -15 to +40 |
18 |
Relative humidity, % |
Up to 90 without condensing |
19 |
Atmospheric pressure, mmHg |
630 – 800 |
20 |
Overall dimensions, mm |
510х300х413 |
21 |
Weight, kg, max |
38,1 |
- The tester is capable of autonomous operation for up to eight hours on a fully charged battery.
- The tester complies with the most rigorous technical standards, boasting modern electronics, design, and software.
- This tester is a dependable, practical, and user-friendly device.
- It streamlines the testing process, saving both time and money by enabling on-site oil testing at transformer locations.